Description
Product Description:
The Allied Medical Cardiasafe-II Defibrillator is an advanced, multi-functional life-saving device that combines defibrillation, pacing, and monitoring technologies into a compact, durable form. Designed for rapid and effective response in critical situations, it integrates manual and AED defibrillation, external pacing, thermal recording, and real-time patient monitoring — all supported by a 7" high-resolution touchscreen. Built for both hospital and emergency use, it features robust battery backup, large data storage, and a lightweight design for enhanced portability.
Key Features:
| Category | Specification |
|---|---|
| Standard Configuration | AED, Pacer, RESP, Thermal Recorder, 360J |
| Display | 7" TFT Screen, 800x480 resolution |
| Size | 295mm x 252mm x 316mm |
| Weight | 6.5 kg |
| Max Displayed Waveforms | 4 |
| Operating Temperature | 0–45°C |
| Operating Humidity | 10%–95% non-condensing |
| Ingress Protection | IP44 |
| Power Supply | 100–240V, 50/60Hz ±3Hz |
| Battery Type | Lithium-ion |
| Battery Backup | Monitoring Mode: ≥6 hours; Pacing Mode: 4.5 hours |
| Defibrillator Modes | Manual, AED, Synchronous |
| Charge Time (AC) | < 6 seconds |
| Patient Impedance | 20–300Ω (External Defib) |
| Manual Energy Range | 1–360J (25 levels: 1–10J, 15–300J, 360J) |
| AED Energy Range | 100–360J (Adjustable) |
| AED Shock Count | Adjustable: 1, 2, or 3 times |
| AED Detectable Rhythms | VF & VT |
| Waveform | Biphasic, Truncated Exponential, with Impedance Compensation |
| Recorder Type | Built-in Thermal Array (max 3 waveform channels) |
| ECG Leads | 3-lead, 5-lead, AUTO |
| ECG Sweep Speeds | 6.25 / 12.5 / 25 / 50 mm/s |
| Heart Rate Range | Adult: 15–300 bpm; Pediatric: 15–350 bpm |
| Heart Rate Accuracy | ±1 bpm |
| CMRR (Common Mode Rej.) | Monitoring/Surgery/ST: >105dB; Diagnosis: >90dB |
| Respiration Method | Thoracic Impedance |
| Resp. Rate Range | Adult: 0–120 rpm; Pediatric: 0–150 rpm |
| Resp. Accuracy | 7–150rpm: ±2rpm or ±2%; 0–6rpm: Unspecified |
| Pacing Mode | On-demand or Fixed |
| Pacing Pulse Width | 20 ms or 40 ms |
| Pacing Accuracy | ±15% (Pulse Width); ±1ppm or ±1.5% (Frequency); ±5% or ±5mA (Output) |
| Pacing Frequency | 30–210 ppm |
| Pacing Output Range | 0–200 mA |
| Interfaces | USB, RJ45, Multi-functional Connector |
| Voice Recording Capacity | Max 240 mins |
| Event Memory | Alarm: 200 groups; Patient Events: 1000; NIBP: 2000 groups |
| Trend Data Storage | 160 hours |
| Waveform Review Storage | 10 minutes |